Vacuum Deaeration System
Capacity: 20 hL/h
The Vacuum Deaeration System removes dissolved oxygen from water in two stages: first under vacuum in the primary tank, then by CO₂ stripping in the secondary tank. Both stages run at room temperature. The system treats up to 20 hL/h, with dissolved oxygen in the treated water specified at less than 0.1 ppm.
It is tested before delivery and arrives mounted on its frame. A Siemens S7-200 SMART PLC with a 7-inch touchscreen runs the system in automatic or jog mode, and a CIP programme for cleaning the whole system is preset in the controls. A 40 hL stainless steel water storage tank is included.
Oxygen Removal
-
01
Two-Stage Deaeration
Water is deaerated under vacuum in the primary tank, then stripped with CO₂ in the secondary tank. Dissolved oxygen in the treated water is specified at less than 0.1 ppm.
-
02
Precision-Machined Atomisers
Each atomiser is machined in a single setup on a CNC machining centre, which gives a consistent spray and makes CO₂ stripping in the secondary tank more effective.
-
03
Water-Ring Vacuum Pump
A 2BV2060 water-ring vacuum pump with a stainless steel pump head takes the system down to −0.09 MPa (−0.9 bar).
Control & Hygiene
-
04
Siemens PLC Control
A Siemens S7-200 SMART PLC with a 7-inch touchscreen, automatic and jog modes, and an RS485 port for connecting the system to a central control room.
-
05
Level and Flow Monitoring
A level gauge suited to foaming liquids controls the level in the primary tank, and flowmeters on the water and CO₂ lines let the operator check working conditions.
-
06
Preset CIP Programme
A cleaning programme is preset in the control system, so the whole system can be cleaned in place. All parts in contact with the water are stainless steel, with heat-resistant seals.
Available configurations
-
Deaeration Unit
Primary and secondary deaeration tanks in SUS304 (Ø250 × 2000 mm each), two 1.5 kW centrifugal pressure pumps, two atomisers, water and CO₂ flowmeters, DN25 pneumatic and manual butterfly valves, and a CIP adapter plate, all on one frame.
-
Vacuum Unit
2BV2060 water-ring vacuum pump (0.9 kW, SUS304 pump head) with check valve and gas–water separator, reaching −0.09 MPa.
-
CO₂ Control
DN10 flowmeter and manual regulating valve, DN15 pneumatic angle seat valve and a pressure-stabilising valve on the CO₂ supply.
-
Control System
Stainless steel control cabinet with Schneider electrical components, SMC solenoid pilot valves, Siemens S7-200 SMART PLC and 7-inch touchscreen. The operator panel layout can be chosen to suit the installation.
-
40 hL Water Storage Tank
Atmospheric stainless steel tank with cone top and bottom, 40 hL working and 49.2 hL total volume, OD 1800 × 2950 mm. Inside 2B finish, pickled and passivated, Ra ≤ 0.8 µm; outer cladding #4 finish.
| Parameter | Value | Unit / Notes |
|---|---|---|
| Process | Vacuum, then CO₂ stripping | At room temperature |
| Capacity | 20 hL/h | 2 m³/h maximum |
| Dissolved Oxygen | < 0.1 ppm | Treated water |
| Skid Dimensions | 2500 × 1200 × 2300 mm | Excluding storage tank |
| Deaeration Tanks | 2 × Ø250 × 2000 mm | SUS304, primary and secondary |
| Pressure Pumps | 2 × 1.5 kW | 2 m³/h each, 52 m head |
| Vacuum Pump | 2BV2060 water ring, 0.9 kW | SUS304 pump head |
| Vacuum | −0.09 MPa | −0.9 bar |
| Vacuum Pump Service Water | < 15 °C | Circulating water |
| Installed Power | 5 kW | Total |
| Control | Siemens S7-200 SMART PLC | 7″ touchscreen, automatic and jog modes |
| Communication | RS485 | To central control room |
| Cleaning | Preset CIP programme | CIP adapter plate fitted |
| Water Supply | 0.4 MPa (4 bar) | Line pressure at inlet |
| CO₂ Supply | ≥ 99.995% purity | ≥ 0.1 MPa (1 bar) |
| Compressed Air | > 0.55 MPa (5.5 bar) | Filtered and dried |
| Product-Contact Parts | Stainless steel | Heat-resistant seals |
| Storage Tank Volume | 40 hL working / 49.2 hL total | 23% headspace |
| Storage Tank Size | OD 1800 × 2950 mm | Atmospheric design |
| Storage Tank Sheet | Shell 2 mm, top head 4 mm, bottom head 2 mm | Stainless steel |
| Storage Tank Finish | Inside 2B, Ra ≤ 0.8 µm | Pickled and passivated; cladding #4 |